Evaluating strength at ultra-high temperatures—Methods and results
Review articleOpen access
2008/06/15 Full-length article DOI: 10.1016/j.msea.2006.09.171
Journal: Materials Science and Engineering: A
Abstract:
AbstractProprietary equipment for mechanical testing at ultra-high temperatures by ohmic heating is outlined. Strain is measured with a video extensometer with an accuracy of up to Δε¯≈±0.00025%. Stability and accuracy of the test system are evaluated on Pt- and refractory alloys. These specially designed and built test facilities are compared to commercially available high-vacuum test chambers with tungsten heater.
Request full text